Compare commits
1 Commits
production
...
MSA-2385-1
| Author | SHA1 | Date | |
|---|---|---|---|
|
|
1f8db8c6bd |
@@ -0,0 +1,481 @@
|
||||
/**
|
||||
* Fibaro Wall Plug ZW5
|
||||
*/
|
||||
metadata {
|
||||
definition (name: "Fibaro Wall Plug US ZW5", namespace: "FibarGroup", author: "Fibar Group") {
|
||||
capability "Switch"
|
||||
capability "Energy Meter"
|
||||
capability "Power Meter"
|
||||
capability "Configuration"
|
||||
capability "Health Check"
|
||||
|
||||
command "reset"
|
||||
command "refresh"
|
||||
|
||||
fingerprint type: "1001", mfr: "0072", cc:"5E,55,98,9F,6C,56", sec:"86,25,85,8E,59,72,5A,73,32,70,71,75,60,7A"
|
||||
}
|
||||
|
||||
tiles (scale: 2) {
|
||||
multiAttributeTile(name:"switch", type: "lighting", width: 3, height: 4, canChangeIcon: true){
|
||||
tileAttribute ("device.switch", key: "PRIMARY_CONTROL") {
|
||||
attributeState "off", label: 'Off', action: "switch.on", icon: "https://s3-eu-west-1.amazonaws.com/fibaro-smartthings/wallPlugUS/plug_us_off.png", backgroundColor: "#ffffff"
|
||||
attributeState "on", label: 'On', action: "switch.off", icon: "https://s3-eu-west-1.amazonaws.com/fibaro-smartthings/wallPlugUS/plug_us_blue.png", backgroundColor: "#00a0dc"
|
||||
}
|
||||
tileAttribute("device.multiStatus", key:"SECONDARY_CONTROL") {
|
||||
attributeState("multiStatus", label:'${currentValue}')
|
||||
}
|
||||
}
|
||||
valueTile("power", "device.power", decoration: "flat", width: 2, height: 2) {
|
||||
state "power", label:'${currentValue}\nW', action:"refresh"
|
||||
}
|
||||
valueTile("energy", "device.energy", decoration: "flat", width: 2, height: 2) {
|
||||
state "energy", label:'${currentValue}\nkWh', action:"refresh"
|
||||
}
|
||||
valueTile("reset", "device.energy", decoration: "flat", width: 2, height: 2) {
|
||||
state "reset", label:'reset\nkWh', action:"reset"
|
||||
}
|
||||
}
|
||||
|
||||
preferences {
|
||||
|
||||
input (
|
||||
title: "Fibaro Wall Plug manual",
|
||||
description: "Tap to view the manual.",
|
||||
image: "https://s3-eu-west-1.amazonaws.com/fibaro-smartthings/wallPlugUS/plug_us_blue.png",
|
||||
//url: "http://manuals.fibaro.com/content/manuals/en/FGWPEF-102/FGWPEF-102-EN-A-v2.0.pdf",
|
||||
type: "href",
|
||||
element: "href"
|
||||
)
|
||||
|
||||
parameterMap().each {
|
||||
input (
|
||||
title: "${it.num}. ${it.title}",
|
||||
description: it.descr,
|
||||
type: "paragraph",
|
||||
element: "paragraph"
|
||||
)
|
||||
|
||||
input (
|
||||
name: it.key,
|
||||
title: null,
|
||||
description: it.defValDescr,
|
||||
type: it.type,
|
||||
options: it.options,
|
||||
range: (it.min != null && it.max != null) ? "${it.min}..${it.max}" : null,
|
||||
defaultValue: it.def,
|
||||
required: false
|
||||
)
|
||||
}
|
||||
|
||||
input ( name: "logging", title: "Logging", type: "boolean", required: false )
|
||||
}
|
||||
}
|
||||
|
||||
def test(options, defValue){
|
||||
def mapToString = "$options"
|
||||
def stringToList = mapToString.split(',').collect{it as String}
|
||||
def result = stringToList.get(0).substring(3)
|
||||
return result
|
||||
}
|
||||
|
||||
//UI and tile functions
|
||||
def on() {
|
||||
log.warn "on"
|
||||
sendEvent(name: "switch", value: "on", isStateChange: true, displayed: false)
|
||||
encap(zwave.basicV1.basicSet(value: 0xFF))
|
||||
}
|
||||
|
||||
def off() {
|
||||
log.warn "off"
|
||||
sendEvent(name: "switch", value: "off", isStateChange: true, displayed: false)
|
||||
encap(zwave.basicV1.basicSet(value: 0))
|
||||
|
||||
}
|
||||
|
||||
def reset() {
|
||||
def cmds = []
|
||||
cmds << [zwave.meterV3.meterReset(), 1]
|
||||
cmds << [zwave.meterV3.meterGet(scale: 0), 1]
|
||||
cmds << [zwave.meterV3.meterGet(scale: 2), 1]
|
||||
encapSequence(cmds,1000)
|
||||
}
|
||||
|
||||
def refresh() {
|
||||
def cmds = []
|
||||
cmds << [zwave.meterV3.meterGet(scale: 0), 1]
|
||||
cmds << [zwave.meterV3.meterGet(scale: 2), 1]
|
||||
encapSequence(cmds,1000)
|
||||
}
|
||||
|
||||
def childReset(){
|
||||
def cmds = []
|
||||
cmds << response(encap(zwave.meterV3.meterReset(), 2))
|
||||
cmds << response(encap(zwave.meterV3.meterGet(scale: 0), 2))
|
||||
cmds << response(encap(zwave.meterV3.meterGet(scale: 2), 2))
|
||||
sendHubCommand(cmds,1000)
|
||||
}
|
||||
|
||||
def childRefresh(){
|
||||
def cmds = []
|
||||
cmds << response(encap(zwave.meterV3.meterGet(scale: 0), 2))
|
||||
cmds << response(encap(zwave.meterV3.meterGet(scale: 2), 2))
|
||||
sendHubCommand(cmds,1000)
|
||||
}
|
||||
|
||||
//Configuration and synchronization
|
||||
def updated() {
|
||||
if ( state.lastUpdated && (now() - state.lastUpdated) < 500 ) return
|
||||
def cmds = []
|
||||
log.warn "Executing updated"
|
||||
if (!childDevices) {
|
||||
createChildDevices()
|
||||
}
|
||||
if (device.currentValue("numberOfButtons") != 6) { sendEvent(name: "numberOfButtons", value: 6) }
|
||||
state.lastUpdated = now()
|
||||
syncStart()
|
||||
}
|
||||
|
||||
def configure() {
|
||||
def cmds = []
|
||||
cmds << zwave.multiChannelAssociationV2.multiChannelAssociationGet(groupingIdentifier:1)
|
||||
cmds << zwave.basicV1.basicSet(value: 0)
|
||||
encapSequence(cmds,1000)
|
||||
}
|
||||
|
||||
private syncStart() {
|
||||
boolean syncNeeded = false
|
||||
Integer settingValue = null
|
||||
parameterMap().each {
|
||||
if(settings."$it.key" != null) {
|
||||
settingValue = settings."$it.key" as Integer
|
||||
if (state."$it.key" == null) { state."$it.key" = [value: null, state: "synced"] }
|
||||
if (state."$it.key".value != settingValue || state."$it.key".state != "synced" ) {
|
||||
state."$it.key".value = settingValue
|
||||
state."$it.key".state = "notSynced"
|
||||
syncNeeded = true
|
||||
}
|
||||
}
|
||||
}
|
||||
if ( syncNeeded ) {
|
||||
logging("sync needed.", "info")
|
||||
syncNext()
|
||||
}
|
||||
}
|
||||
|
||||
private syncNext() {
|
||||
logging("Executing syncNext()","info")
|
||||
def cmds = []
|
||||
for ( param in parameterMap() ) {
|
||||
if ( state."$param.key"?.value != null && state."$param.key"?.state in ["notSynced","inProgress"] ) {
|
||||
multiStatusEvent("Sync in progress. (param: ${param.num})", true)
|
||||
state."$param.key"?.state = "inProgress"
|
||||
|
||||
cmds << response(encap(zwave.configurationV2.configurationSet(configurationValue: intToParam(state."$param.key".value, param.size), parameterNumber: param.num, size: param.size)))
|
||||
cmds << response(encap(zwave.configurationV2.configurationGet(parameterNumber: param.num)))
|
||||
break
|
||||
}
|
||||
}
|
||||
if (cmds) {
|
||||
runIn(10, "syncCheck")
|
||||
sendHubCommand(cmds,1000)
|
||||
} else {
|
||||
runIn(1, "syncCheck")
|
||||
}
|
||||
}
|
||||
|
||||
private syncCheck() {
|
||||
logging("Executing syncCheck()","info")
|
||||
def failed = []
|
||||
def incorrect = []
|
||||
def notSynced = []
|
||||
parameterMap().each {
|
||||
if (state."$it.key"?.state == "incorrect" ) {
|
||||
incorrect << it
|
||||
} else if ( state."$it.key"?.state == "failed" ) {
|
||||
failed << it
|
||||
} else if ( state."$it.key"?.state in ["inProgress","notSynced"] ) {
|
||||
notSynced << it
|
||||
}
|
||||
}
|
||||
|
||||
if (failed) {
|
||||
multiStatusEvent("Sync failed! Verify parameter: ${failed[0].num}", true, true)
|
||||
} else if (incorrect) {
|
||||
multiStatusEvent("Sync mismatch! Verify parameter: ${incorrect[0].num}", true, true)
|
||||
} else if (notSynced) {
|
||||
multiStatusEvent("Sync incomplete! Open settings and tap Done to try again.", true, true)
|
||||
} else {
|
||||
if (device.currentValue("multiStatus")?.contains("Sync")) { multiStatusEvent("Sync OK.", true, true) }
|
||||
}
|
||||
}
|
||||
|
||||
private createChildDevices() {
|
||||
logging("${device.displayName} - executing createChildDevices()","info")
|
||||
addChildDevice(
|
||||
"Fibaro Wall Plug USB",
|
||||
"${device.deviceNetworkId}-2",
|
||||
null,
|
||||
[completedSetup: true, label: "${device.displayName} (CH2)", isComponent: false, componentName: "ch2", componentLabel: "Channel 2"]
|
||||
)
|
||||
}
|
||||
|
||||
private physicalgraph.app.ChildDeviceWrapper getChild(Integer childNum) {
|
||||
return childDevices.find({ it.deviceNetworkId == "${device.deviceNetworkId}-${childNum}" })
|
||||
}
|
||||
|
||||
private multiStatusEvent(String statusValue, boolean force = false, boolean display = false) {
|
||||
if (!device.currentValue("multiStatus")?.contains("Sync") || device.currentValue("multiStatus") == "Sync OK." || force) {
|
||||
sendEvent(name: "multiStatus", value: statusValue, descriptionText: statusValue, displayed: display)
|
||||
}
|
||||
}
|
||||
|
||||
private ch2MultiStatusEvent(String statusValue, boolean force = false, boolean display = false) {
|
||||
getChild(2)?.sendEvent(name: "multiStatus", value: statusValue, descriptionText: statusValue, displayed: display)
|
||||
|
||||
}
|
||||
//event handlers related to configuration and sync
|
||||
def zwaveEvent(physicalgraph.zwave.commands.configurationv2.ConfigurationReport cmd) {
|
||||
def paramKey = parameterMap().find( {it.num == cmd.parameterNumber } ).key
|
||||
logging("Parameter ${paramKey} value is ${cmd.scaledConfigurationValue} expected " + state."$paramKey".value, "info")
|
||||
state."$paramKey".state = (state."$paramKey".value == cmd.scaledConfigurationValue) ? "synced" : "incorrect"
|
||||
syncNext()
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.applicationstatusv1.ApplicationRejectedRequest cmd) {
|
||||
logging("rejected request!","warn")
|
||||
for ( param in parameterMap() ) {
|
||||
if ( state."$param.key"?.state == "inProgress" ) {
|
||||
state."$param.key"?.state = "failed"
|
||||
break
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.multichannelassociationv2.MultiChannelAssociationReport cmd) {
|
||||
def cmds = []
|
||||
if (cmd.groupingIdentifier == 1) {
|
||||
if (cmd.nodeId != [0, zwaveHubNodeId, 1]) {
|
||||
log.debug "${device.displayName} - incorrect MultiChannel Association for Group 1! nodeId: ${cmd.nodeId} will be changed to [0, ${zwaveHubNodeId}, 1]"
|
||||
cmds << zwave.multiChannelAssociationV2.multiChannelAssociationRemove(groupingIdentifier: 1)
|
||||
cmds << zwave.multiChannelAssociationV2.multiChannelAssociationSet(groupingIdentifier: 1, nodeId: [0,zwaveHubNodeId,1])
|
||||
} else {
|
||||
logging("${device.displayName} - MultiChannel Association for Group 1 correct.","info")
|
||||
}
|
||||
}
|
||||
if (cmds) { [response(encapSequence(cmds, 1000))] }
|
||||
}
|
||||
|
||||
//event handlers
|
||||
def zwaveEvent(physicalgraph.zwave.commands.basicv1.BasicReport cmd) {
|
||||
//ignore
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.switchbinaryv1.SwitchBinaryReport cmd, ep=null) {
|
||||
log.warn "SwitchBinaryReport"
|
||||
logging("${device.displayName} - SwitchBinaryReport received, value: ${cmd.value}","info")
|
||||
sendEvent([name: "switch", value: (cmd.value == 0 ) ? "off": "on"])
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.meterv3.MeterReport cmd, ep=null) {
|
||||
log.warn "${device.displayName} - MeterReport received, value: ${cmd.scaledMeterValue} scale: ${cmd.scale} ep: $ep"
|
||||
if (ep==1) {
|
||||
log.warn "chanell1"
|
||||
switch (cmd.scale) {
|
||||
case 0: sendEvent([name: "energy", value: cmd.scaledMeterValue, unit: "kWh"]); break;
|
||||
case 2: sendEvent([name: "power", value: cmd.scaledMeterValue, unit: "W"]); break;
|
||||
}
|
||||
if (device.currentValue("energy") != null) {multiStatusEvent("${device.currentValue("power")} W / ${device.currentValue("energy")} kWh")}
|
||||
else {multiStatusEvent("${device.currentValue("power")} W / 0.00 kWh")}
|
||||
}
|
||||
|
||||
if (ep==2) {
|
||||
log.warn "chanell2"
|
||||
switch (cmd.scale) {
|
||||
case 0: getChild(2)?.sendEvent([name: "energy", value: cmd.scaledMeterValue, unit: "kWh"]); break;
|
||||
case 2: getChild(2)?.sendEvent([name: "power", value: cmd.scaledMeterValue, unit: "W"]); break;
|
||||
}
|
||||
if (device.currentValue("energy") != null) {ch2MultiStatusEvent("${getChild(2)?.currentValue("power")} W / ${getChild(2)?.currentValue("energy")} kWh")}
|
||||
else {ch2MultiStatusEvent("${getChild(2)?.currentValue("power")} W / 0.00 kWh")}
|
||||
}
|
||||
}
|
||||
|
||||
/*
|
||||
####################
|
||||
## Z-Wave Toolkit ##
|
||||
####################
|
||||
*/
|
||||
def parse(String description) {
|
||||
def result = []
|
||||
logging("${device.displayName} - Parsing: ${description}")
|
||||
if (description.startsWith("Err 106")) {
|
||||
result = createEvent(
|
||||
descriptionText: "Failed to complete the network security key exchange. If you are unable to receive data from it, you must remove it from your network and add it again.",
|
||||
eventType: "ALERT",
|
||||
name: "secureInclusion",
|
||||
value: "failed",
|
||||
displayed: true,
|
||||
)
|
||||
} else if (description == "updated") {
|
||||
return null
|
||||
} else {
|
||||
def cmd = zwave.parse(description, cmdVersions())
|
||||
if (cmd) {
|
||||
logging("${device.displayName} - Parsed: ${cmd}")
|
||||
zwaveEvent(cmd)
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.securityv1.SecurityMessageEncapsulation cmd) {
|
||||
def encapsulatedCommand = cmd.encapsulatedCommand(cmdVersions())
|
||||
if (encapsulatedCommand) {
|
||||
logging("${device.displayName} - Parsed SecurityMessageEncapsulation into: ${encapsulatedCommand}")
|
||||
zwaveEvent(encapsulatedCommand)
|
||||
} else {
|
||||
log.warn "Unable to extract secure cmd from $cmd"
|
||||
}
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.crc16encapv1.Crc16Encap cmd) {
|
||||
def version = cmdVersions()[cmd.commandClass as Integer]
|
||||
def ccObj = version ? zwave.commandClass(cmd.commandClass, version) : zwave.commandClass(cmd.commandClass)
|
||||
def encapsulatedCommand = ccObj?.command(cmd.command)?.parse(cmd.data)
|
||||
if (encapsulatedCommand) {
|
||||
logging("${device.displayName} - Parsed Crc16Encap into: ${encapsulatedCommand}")
|
||||
zwaveEvent(encapsulatedCommand)
|
||||
} else {
|
||||
log.warn "Could not extract crc16 command from $cmd"
|
||||
}
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.securityv1.SecurityCommandsSupportedReport cmd) {
|
||||
log.debug "SecurityCommandsSupportedReport"
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.securityv1.NetworkKeyVerify cmd){
|
||||
log.debug "NetworkKeyVerify"
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.securityv1.SecuritySchemeReport cmd){
|
||||
log.debug "SecuritySchemeReport"
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.applicationstatusv1.ApplicationBusy cmd) {
|
||||
log.debug "ApplicationBusy"
|
||||
}
|
||||
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.multichannelv3.MultiChannelCmdEncap cmd) {
|
||||
def encapsulatedCommand = cmd.encapsulatedCommand(cmdVersions())
|
||||
if (encapsulatedCommand) {
|
||||
logging("${device.displayName} - Parsed MultiChannelCmdEncap ${encapsulatedCommand}")
|
||||
zwaveEvent(encapsulatedCommand, cmd.sourceEndPoint as Integer)
|
||||
} else {
|
||||
log.warn "Unable to extract MultiChannel command from $cmd"
|
||||
}
|
||||
}
|
||||
|
||||
private logging(text, type = "debug") {
|
||||
if (settings.logging == "true") {
|
||||
log."$type" text
|
||||
}
|
||||
}
|
||||
|
||||
private secEncap(physicalgraph.zwave.Command cmd) {
|
||||
logging("${device.displayName} - encapsulating command using Secure Encapsulation, command: $cmd","info")
|
||||
zwave.securityV1.securityMessageEncapsulation().encapsulate(cmd).format()
|
||||
}
|
||||
|
||||
private crcEncap(physicalgraph.zwave.Command cmd) {
|
||||
logging("${device.displayName} - encapsulating command using CRC16 Encapsulation, command: $cmd","info")
|
||||
zwave.crc16EncapV1.crc16Encap().encapsulate(cmd).format()
|
||||
}
|
||||
|
||||
private multiEncap(physicalgraph.zwave.Command cmd, Integer ep) {
|
||||
logging("${device.displayName} - encapsulating command using MultiChannel Encapsulation, ep: $ep command: $cmd","info")
|
||||
zwave.multiChannelV3.multiChannelCmdEncap(destinationEndPoint:ep).encapsulate(cmd)
|
||||
}
|
||||
|
||||
private encap(physicalgraph.zwave.Command cmd, Integer ep) {
|
||||
encap(multiEncap(cmd, ep))
|
||||
}
|
||||
|
||||
private encap(List encapList) {
|
||||
encap(encapList[0], encapList[1])
|
||||
}
|
||||
|
||||
private encap(Map encapMap) {
|
||||
encap(encapMap.cmd, encapMap.ep)
|
||||
}
|
||||
|
||||
|
||||
private encap(physicalgraph.zwave.Command cmd) {
|
||||
if (zwaveInfo.zw.contains("s")) {
|
||||
secEncap(cmd)
|
||||
} else if (zwaveInfo.cc.contains("56")){
|
||||
crcEncap(cmd)
|
||||
} else {
|
||||
logging("${device.displayName} - no encapsulation supported for command: $cmd","info")
|
||||
cmd.format()
|
||||
}
|
||||
}
|
||||
|
||||
private encapSequence(cmds, Integer delay=250) {
|
||||
delayBetween(cmds.collect{ encap(it) }, delay)
|
||||
}
|
||||
|
||||
private encapSequence(cmds, Integer delay, Integer ep) {
|
||||
delayBetween(cmds.collect{ encap(it, ep) }, delay)
|
||||
}
|
||||
|
||||
private List intToParam(Long value, Integer size = 1) {
|
||||
def result = []
|
||||
size.times {
|
||||
result = result.plus(0, (value & 0xFF) as Short)
|
||||
value = (value >> 8)
|
||||
}
|
||||
return result
|
||||
}
|
||||
/*
|
||||
##########################
|
||||
## Device Configuration ##
|
||||
##########################
|
||||
*/
|
||||
private Map cmdVersions() {
|
||||
[0x5E: 2, 0x22 :1, 0x56: 1, 0x59: 2, 0x7A: 4 ,0x32: 3, 0x71: 8, 0x73: 1, 0x98: 1, 0x85: 2, 0x70: 2, 0x72: 2, 0x5A: 1, 0x8E: 2, 0x25: 1, 0x86: 2, 0x55: 2, 0x9F: 1, 0x75: 1, 0x60: 3, 0x6C: 1, 0x20: 1]
|
||||
}
|
||||
|
||||
private parameterMap() {[
|
||||
|
||||
[key: "restoreState", num: 2, size: 1, type: "enum", options: [0: "device remains switched off", 1: "device restores the state"], def: "0", title: "Restore state after power failure",
|
||||
descr: "After the power supply is back on, the Wall Plug can be restored to previous state or remain switched off.", defValDescr: "Device remains switched off (Default)"],
|
||||
[key: "overloadSafety", num: 3, size: 2, type: "number", def: 0, min: 0, max: 18000 , title: "Overload safety switch",
|
||||
descr: "Allows to turn off the controlled device in case of exceeding the defined power;\n0 - function inactive\n10-18000 (1.0-1800.0W, step 0.1W)\n To calculate the value of parameter, multiply the power in Watts by 10 for example: 50 W x 10 = 500 Where: 50 W – the power of device connected to Wall Plug; 500 - value of parameter."],
|
||||
[key: "standardPowerReports", num: 11, size: 1, type: "number", def: 15, min: 1, max: 100, title: "Standard power reports",
|
||||
descr: "This parameter determines the minimum percentage change in active power that will result in sending a power report.\n1-99 - power change in percent\n100 - reports are disabled"],
|
||||
[key: "periodicReports", num: 14, size: 2, type: "number", def: 3600, min: 0, max: 32400, title: "Periodic power and energy reports",
|
||||
descr: "Time period between independent reports.\n0 - periodic reports inactive\n5-32400 (in seconds)"],
|
||||
[key: "ringColorOn", num: 41, size: 1, type: "enum", options: [
|
||||
0: "Off",
|
||||
1: "Load based - continuous",
|
||||
2: "Load based - steps",
|
||||
3: "White",
|
||||
4: "Red",
|
||||
5: "Green",
|
||||
6: "Blue",
|
||||
7: "Yellow",
|
||||
8: "Cyan",
|
||||
9: "Magenta"
|
||||
], def: "1", title: "Ring LED color when on", descr: "Ring LED colour when the device is ON.", defValDescr: "Load based - continuous (Default)"],
|
||||
[key: "ringColorOff", num: 42, size: 1, type: "enum", options: [
|
||||
0: "Off",
|
||||
1: "Last measured power",
|
||||
3: "White",
|
||||
4: "Red",
|
||||
5: "Green",
|
||||
6: "Blue",
|
||||
7: "Yellow",
|
||||
8: "Cyan",
|
||||
9: "Magenta"
|
||||
], def: "0", title: "Ring LED color when off", descr: "Ring LED colour when the device is OFF.", defValDescr: "Off (Default)"]
|
||||
]}
|
||||
Reference in New Issue
Block a user