@@ -11,272 +11,139 @@
* for the specific language governing permissions and limitations under the License.
*
*/
metadata {
definition (name: "Dimmer Switch", namespace: "smartthings", author: "SmartThings", ocfDeviceType: "oic.d.light") {
capability "Switch Level"
capability "Actuator"
capability "Indicator"
capability "Switch"
capability "Refresh"
capability "Sensor"
capability "Health Check"
capability "Light"
definition (name: "ZigBee Dimmer", namespace: "smartthings", author: "SmartThings", ocfDeviceType: "oic.d.light", runLocally: true, minHubCoreVersion: '000.019.00012', executeCommandsLocally: true) {
capability "Actuator"
capability "Configuration"
capability "Refresh"
capability "Switch"
capability "Switch Level"
capability "Health Check"
capability "Light"
fingerprint mfr:"0063", prod:"4457", deviceJoinName: "GE In-Wall Smart Dimmer"
fingerprint mfr:"0063", prod:"4944", deviceJoinName: "GE In-Wall Smart Dimmer"
fingerprint mfr:"0063", prod:"5044", deviceJoinName: "GE Plug-In Smart Dimmer"
}
simulator {
status "on": "command: 2003, payload: FF"
status "off": "command: 2003, payload: 00"
status "09%": "command: 2003, payload: 09"
status "10%": "command: 2003, payload: 0A"
status "33%": "command: 2003, payload: 21"
status "66%": "command: 2003, payload: 42"
status "99%": "command: 2003, payload: 63"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 0B04, FC0F", outClusters: "0019", manufacturer: "OSRAM", model: "LIGHTIFY A19 ON/OFF/DIM", deviceJoinName: "SYLVANIA Smart A19 Soft White"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, FC0F", outClusters: "0019", manufacturer: "OSRAM", model: "LIGHTIFY A19 ON/OFF/DIM 10 Year", deviceJoinName: "SYLVANIA Smart 10-Year A19"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, FF00", outClusters: "0019", manufacturer: "MRVL", model: "MZ100", deviceJoinName: "Wemo Bulb"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 0B05", outClusters: "0019", manufacturer: "OSRAM SYLVANIA", model: "iQBR30", deviceJoinName: "Sylvania Ultra iQ"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, FC0F", outClusters: "0019", manufacturer: "OSRAM", model: "LIGHTIFY PAR38 ON/OFF/DIM", deviceJoinName: "SYLVANIA Smart PAR38 Soft White"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 0B04, FC0F", outClusters: "0019", manufacturer: "OSRAM", model: "LIGHTIFY BR ON/OFF/DIM", deviceJoinName: "SYLVANIA Smart BR30 Soft White"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 0702, 0B05", outClusters: "0019", manufacturer: "sengled", model: "E11-G13", deviceJoinName: "Sengled Element Classic"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 0702, 0B05", outClusters: "0019", manufacturer: "sengled", model: "E11-G14", deviceJoinName: "Sengled Element Classic"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 0702, 0B05", outClusters: "0019", manufacturer: "sengled", model: "E11-G23", deviceJoinName: "Sengled Element Classic"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 0702, 0B05", outClusters: "0019", manufacturer: "sengled", model: "E11-G33", deviceJoinName: "Sengled Element Classic"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 0702, 0B05", outClusters: "0019", manufacturer: "sengled", model: "E12-N13", deviceJoinName: "Sengled Element Classic"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 0702, 0B05", outClusters: "0019", manufacturer: "sengled", model: "E12-N14", deviceJoinName: "Sengled Element Classic"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 0702, 0B05", outClusters: "0019", manufacturer: "sengled", model: "E12-N15", deviceJoinName: "Sengled Element Classic"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008", outClusters: "0003, 0006, 0008, 0019, 0406", manufacturer: "Leviton", model: "DL6HD", deviceJoinName: "Leviton Dimmer Switch"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008", outClusters: "0003, 0006, 0008, 0019, 0406", manufacturer: "Leviton", model: "DL3HL", deviceJoinName: "Leviton Lumina RF Plug-In Dimmer"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008", outClusters: "0003, 0006, 0008, 0019, 0406", manufacturer: "Leviton", model: "DL1KD", deviceJoinName: "Leviton Lumina RF Dimmer Switch"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 0300, 0B04, 0B05, FC01, FC08", outClusters: "0003, 0019", manufacturer: "LEDVANCE", model: "A19 W 10 year", deviceJoinName: "SYLVANIA Smart 10Y A19 Soft White"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 0300, 0B05, FC01", outClusters: "0003, 0019", manufacturer: "LEDVANCE", model: "BR30 W 10 year", deviceJoinName: "SYLVANIA Smart 10Y BR30 Soft White"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 0300, 0B05, FC01", outClusters: "0003, 0019", manufacturer: "LEDVANCE", model: "PAR38 W 10 year", deviceJoinName: "SYLVANIA Smart 10Y PAR38 Soft White"
}
// reply messages
reply "2001FF,delay 5000,2602": "command: 2603, payload: FF"
reply "200100,delay 5000,2602": "command: 2603, payload: 00"
reply "200119,delay 5000,2602": "command: 2603, payload: 19"
reply "200132,delay 5000,2602": "command: 2603, payload: 32"
reply "20014B,delay 5000,2602": "command: 2603, payload: 4B"
reply "200163,delay 5000,2602": "command: 2603, payload: 63"
}
preferences {
input "ledIndicator", "enum", title: "LED Indicator", description: "Turn LED indicator... ", required: false, options:["on": "When On", "off": "When Off", "never": "Never"], defaultValue: "off"
}
tiles(scale: 2) {
multiAttributeTile(name:"switch", type: "lighting", width: 6, height: 4, canChangeIcon: true){
tileAttribute ("device.switch", key: "PRIMARY_CONTROL") {
attributeState "on", label:'${name}', action:"switch.off", icon:"st.switches.switch.on", backgroundColor:"#00a0dc", nextState:"turningOff"
attributeState "off", label:'${name}', action:"switch.on", icon:"st.switches.switch.off", backgroundColor:"#ffffff", nextState:"turningOn"
attributeState "turningOn", label:'${name}', action:"switch.off", icon:"st.switches.switch.on", backgroundColor:"#00a0dc", nextState:"turningOff"
attributeState "turningOff", label:'${name}', action:"switch.on", icon:"st.switches.switch.off", backgroundColor:"#ffffff", nextState:"turningOn"
}
tileAttribute ("device.level", key: "SLIDER_CONTROL") {
attributeState "level", action:"switch level.setLevel"
}
}
standardTile("indicator", "device.indicatorStatus", width: 2, height: 2, inactiveLabel: false, decoration: "flat") {
state "when off", action:"indicator.indicatorWhenOn", icon:"st.indicators.lit-when-off"
state "when on", action:"indicator.indicatorNever", icon:"st.indicators.lit-when-on"
state "never", action:"indicator.indicatorWhenOff", icon:"st.indicators.never-lit"
}
standardTile("refresh", "device.switch", width: 2, height: 2, inactiveLabel: false, decoration: "flat") {
state "default", label:'', action:"refresh.refresh", icon:"st.secondary.refresh"
}
valueTile("level", "device.level", inactiveLabel: false, decoration: "flat", width: 2, height: 2) {
state "level", label:'${currentValue} %', unit:"%", backgroundColor:"#ffffff"
}
main(["switch"])
details(["switch", "level", "refresh"])
}
}
def installed() {
// Device-Watch simply pings if no device events received for 32min(checkInterval)
sendEvent(name: "checkInterval", value: 2 * 15 * 60 + 2 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
response(refresh())
}
def updated(){
// Device-Watch simply pings if no device events received for 32min(checkInterval)
sendEvent(name: "checkInterval", value: 2 * 15 * 60 + 2 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
switch (ledIndicator) {
case "on":
indicatorWhenOn()
break
case "off":
indicatorWhenOff()
break
case "never":
indicatorNever()
break
default:
indicatorWhenOn()
break
tiles(scale: 2) {
multiAttributeTile(name:"switch", type: "lighting", width: 6, height: 4, canChangeIcon: true){
tileAttribute ("device.switch", key: "PRIMARY_CONTROL") {
attributeState "on", label:'${name}', action:"switch.off", icon:"st.switches.light.on", backgroundColor:"#00A0DC", nextState:"turningOff"
attributeState "off", label:'${name}', action:"switch.on", icon:"st.switches.light.off", backgroundColor:"#ffffff", nextState:"turningOn"
attributeState "turningOn", label:'${name}', action:"switch.off", icon:"st.switches.light.on", backgroundColor:"#00A0DC", nextState:"turningOff"
attributeState "turningOff", label:'${name}', action:"switch.on", icon:"st.switches.light.off", backgroundColor:"#ffffff", nextState:"turningOn"
}
tileAttribute ("device.level", key: "SLIDER_CONTROL") {
attributeState "level", action:"switch level.setLevel"
}
}
standardTile("refresh", "device.refresh", inactiveLabel: false, decoration: "flat", width: 2, height: 2) {
state "default", label:"", action:"refresh.refresh", icon:"st.secondary.refresh"
}
main "switch"
details(["switch", "refresh"])
}
}
def getCommandClassVersions() {
[
0x20: 1, // Basic
0x26: 1, // SwitchMultilevel
0x56: 1, // Crc16Encap
0x70: 1, // Configuration
]
}
// Parse incoming device messages to generate events
def parse(String description) {
def result = null
if (description != "updated") {
log.debug "parse() >> zwave.parse($description)"
def cmd = zwave.parse(description, commandClassVersions)
if (cmd) {
result = zwaveEvent(cmd)
}
}
if (result?.name == 'hail' && hubFirmwareLessThan("000.011.00602")) {
result = [result, response(zwave.basicV1.basicGet())]
log.debug "Was hailed: requesting state update"
} else {
log.debug "Parse returned ${result?.descriptionText}"
}
return result
}
log.debug "description is $description"
def zwaveEvent(physicalgraph.zwave.commands.basicv1.BasicReport cmd) {
dimmerEvents(cmd)
}
def zwaveEvent(physicalgraph.zwave.commands.basicv1.BasicSet cmd) {
dimmerEvents(cmd)
}
def zwaveEvent(physicalgraph.zwave.commands.switchmultilevelv1.SwitchMultilevelReport cmd) {
dimmerEvents(cmd)
}
def zwaveEvent(physicalgraph.zwave.commands.switchmultilevelv1.SwitchMultilevelSet cmd) {
dimmerEvents(cmd)
}
private dimmerEvents(physicalgraph.zwave.Command cmd) {
def value = (cmd.value ? "on" : "off")
def result = [createEvent(name: "switch", value: value)]
if (cmd.value && cmd.value <= 100) {
result << createEvent(name: "level", value: cmd.value, unit: "%")
}
return result
}
def zwaveEvent(physicalgraph.zwave.commands.configurationv1.ConfigurationReport cmd) {
log.debug "ConfigurationReport $cmd"
def value = "when off"
if (cmd.configurationValue[0] == 1) {value = "when on"}
if (cmd.configurationValue[0] == 2) {value = "never"}
createEvent([name: "indicatorStatus", value: value])
}
def zwaveEvent(physicalgraph.zwave.commands.hailv1.Hail cmd) {
createEvent([name: "hail", value: "hail", descriptionText: "Switch button was pressed", displayed: false])
}
def zwaveEvent(physicalgraph.zwave.commands.manufacturerspecificv2.ManufacturerSpecificReport cmd) {
log.debug "manufacturerId: ${cmd.manufacturerId}"
log.debug "manufacturerName: ${cmd.manufacturerName}"
log.debug "productId: ${cmd.productId}"
log.debug "productTypeId: ${cmd.productTypeId}"
def msr = String.format("%04X-%04X-%04X", cmd.manufacturerId, cmd.productTypeId, cmd.productId)
updateDataValue("MSR", msr)
updateDataValue("manufacturer", cmd.manufacturerName)
createEvent([descriptionText: "$device.displayName MSR: $msr", isStateChange: false])
}
def zwaveEvent(physicalgraph.zwave.commands.switchmultilevelv1.SwitchMultilevelStopLevelChange cmd) {
[createEvent(name:"switch", value:"on"), response(zwave.switchMultilevelV1.switchMultilevelGet().format())]
}
def zwaveEvent(physicalgraph.zwave.commands.crc16encapv1.Crc16Encap cmd) {
def versions = commandClassVersions
def version = versions[cmd.commandClass as Integer]
def ccObj = version ? zwave.commandClass(cmd.commandClass, version) : zwave.commandClass(cmd.commandClass)
def encapsulatedCommand = ccObj?.command(cmd.command)?.parse(cmd.data)
if (encapsulatedCommand) {
zwaveEvent(encapsulatedCommand)
}
}
def zwaveEvent(physicalgraph.zwave.Command cmd) {
// Handles all Z-Wave commands we aren't interested in
[:]
}
def on() {
delayBetween([
zwave.basicV1.basicSet(value: 0xFF).format(),
zwave.switchMultilevelV1.switchMultilevelGet().format()
],5000)
def event = zigbee.getEvent(description)
if (event) {
if (event.name=="level" && event.value==0) {}
else {
sendEvent(event)
}
} else {
def descMap = zigbee.parseDescriptionAsMap(description)
if (descMap && descMap.clusterInt == 0x0006 && descMap.commandInt == 0x07) {
if (descMap.data[0] == "00") {
log.debug "ON/OFF REPORTING CONFIG RESPONSE: " + cluster
sendEvent(name: "checkInterval", value: 60 * 12, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
} else {
log.warn "ON/OFF REPORTING CONFIG FAILED- error code:${cluster.data[0]}"
}
} else if (device.getDataValue("manufacturer") == "sengled" && descMap && descMap.clusterInt == 0x0008 && descMap.attrInt == 0x0000) {
// This is being done because the sengled element touch/classic incorrectly uses the value 0xFF for the max level.
// Per the ZCL spec for the UINT8 data type 0xFF is an invalid value, and 0xFE should be the max. Here we
// manually handle the invalid attribute value since it will be ignored by getEvent as an invalid value.
// We also set the level of the bulb to 0xFE so future level reports will be 0xFE until it is changed by
// something else.
if (descMap.value.toUpperCase() == "FF") {
descMap.value = "FE"
}
sendHubCommand(zigbee.command(zigbee.LEVEL_CONTROL_CLUSTER, 0x00, "FE0000").collect { new physicalgraph.device.HubAction(it) }, 0)
sendEvent(zigbee.getEventFromAttrData(descMap.clusterInt, descMap.attrInt, descMap.encoding, descMap.value))
} else {
log.warn "DID NOT PARSE MESSAGE for description : $description"
log.debug "${descMap}"
}
}
}
def off() {
delayBetween([
zwave.basicV1.basicSet(value: 0x00).format(),
zwave.switchMultilevelV1.switchMultilevelGet().format()
],5000)
zigbee.off()
}
def on() {
zigbee.on()
}
def setLevel(value) {
log.debug "setLevel >> value: $value"
def valueaux = value as Integer
def level = Math.max(Math.min(valueaux, 99), 0)
if (level > 0) {
sendEvent(name: "switch", value: "on")
} else {
sendEvent(name: "switch", value: "off")
}
sendEvent(name: "level", value: level, unit: "%")
delayBetween ([zwave.basicV1.basicSet(value: level).format(), zwave.switchMultilevelV1.switchMultilevelGet().format()], 5000)
def additionalCmds = []
if (device.getDataValue("model") == "iQBR30" && value.toInteger() > 0) { // Handle iQ bulb not following spec
additionalCmds = zigbee.on()
} else if (device.getDataValue("manufacturer") == "MRVL") { // Handle marvel stack not reporting
additionalCmds = refresh()
}
zigbee.setLevel(value) + additionalCmds
}
def setLevel(value, duration) {
log.debug "setLevel >> value: $value, duration: $duration"
def valueaux = value as Integer
def level = Math.max(Math.min(valueaux, 99), 0)
def dimmingDuration = duration < 128 ? duration : 128 + Math.round(duration / 60)
def getStatusDelay = duration < 128 ? (duration*1000)+2000 : (Math.round(duration / 60)*60*1000)+2000
delayBetween ([zwave.switchMultilevelV2.switchMultilevelSet(value: level, dimmingDuration: dimmingDuration).format(),
zwave.switchMultilevelV1.switchMultilevelGet().format()], getStatusDelay)
}
/**
* PING is used by Device-Watch in attempt to reach the Device
* */
def ping() {
refresh()
return zigbee.onOffRefresh()
}
def refresh() {
log.debug "refresh() is called"
def commands = []
commands << zwave.switchMultilevelV1.switchMultilevelGet().format()
if (getDataValue("MSR") == null) {
commands << zwave.manufacturerSpecificV1.manufacturerSpecificGet().format()
}
delayBetween(commands,100)
zigbee.onOffRefresh() + zigbee.levelRefresh()
}
void indicatorWhenOn() {
sendEvent(name: "indicatorStatus", value: "when on", displayed: false)
sendHubCommand(new physicalgraph.device.HubAction(zwave.configurationV1.configurationSet(configurationValue: [1], parameterNumber: 3, size: 1).format()))
def installed() {
if (((device.getDataValue("manufacturer") == "MRVL") && (device.getDataValue("model") == "MZ100")) || (device.getDataValue("manufacturer") == "OSRAM SYLVANIA") || (device.getDataValue("manufacturer") == "OSRAM")) {
if ((device.currentState("level")?.value == null) || (device.currentState("level")?.value == 0)) {
sendEvent(name: "level", value: 100)
}
}
}
void indicatorWhenOff() {
sendEvent(name: "indicatorStatus", value: "when off", displayed: false)
sendHubCommand(new physicalgraph.device.HubAction(zwave.configurationV1.configurationSet(configurationValue: [0], parameterNumber: 3, size: 1).format()))
}
def configure() {
log.debug "Configuring Reporting and Bindings."
// Device-Watch allows 2 check-in misses from device + ping (plus 1 min lag time)
// enrolls with default periodic reporting until newer 5 min interval is confirmed
sendEvent(name: "checkInterval", value: 2 * 10 * 60 + 1 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
void indicatorNever() {
sendEvent(name: "indicatorStatus", value: "never", displayed: false)
sendHubCommand(new physicalgraph.device.HubAction(zwave.configurationV1.configurationSet(configurationValue: [2], parameterNumber: 3, size: 1).format()))
}
def invertSwitch(invert=true) {
if (invert) {
zwave.configurationV1.configurationSet(configurationValue: [1], parameterNumber: 4, size: 1).format()
}
else {
zwave.configurationV1.configurationSet(configurationValue: [0], parameterNumber: 4, size: 1).format()
}
// OnOff minReportTime 0 seconds, maxReportTime 5 min. Reporting interval if no activity